3. Available Gases
With the lowest boiling point, Helium is used in various applications and industries. It serves as a cryogenic agent to cool superconductive magnetic coils in Magnetic Resonance Imaging (MRI) and Nuclear Magnetic Resonance (NMR) medical equipment. Aside from that, Helium is chemically inert and can be used to create an inert atmosphere for Tungsten Inert Gas (TIG) or Metal Inert Gas (MIG) welding. It is also used for purging, annealing, sputtering, leak checking and etching applications in the Electronics industry.
Supply Mode | Grade | Purity | Impurities | Packaging Available | ||
---|---|---|---|---|---|---|
Cylinder |
Rack |
Tube Trailers |
||||
Packaged Gas Supply |
Balloon gas | - |
- |
● | not included | not included |
Industrial | ≥ 99.999% |
- |
● | ● | not included | |
Purified | ≥ 99.9995% |
Moisture < 2 ppm Oxygen < 2 ppm Hydrocarbons < 0.5 ppm |
● | ● | not included | |
ALPHAGAZ™ 1 | ≥ 99.999% |
Moisture < 2 ppm Oxygen < 2 ppm Hydrocarbons < 0.5 ppm CO < 0.5 ppm CO2 < 0.5 ppm |
● | not included | not included | |
Ultra High Purity | ≥ 99.9999% |
|
● | not included | not included | |
Bulk Supply (Liquid Helium) | Industrial | Contact for further details | not included | not included | ● |
Packaging | Grade | No. of Cylinder(s) | No. of Outlet(s) | Water Capacity (L) | Content (m³) | Gas Pressure (bar) | Valve Connection |
---|---|---|---|---|---|---|---|
Grade Balloon Gas |
No. of Cylinder(s) 1 |
No. of Outlet(s) 1 |
Water Capacity (L) 10 |
Content (m³) 1.4 |
Gas Pressure (bar) 150 |
Valve Connection BS 341 No. 3 |
|
Packaging 40 |
Grade 6.0 |
||||||
Packaging 47 |
Grade 6.6 |
||||||
Packaging 50 |
Grade 7.0 |
||||||
Packaging Industrial |
Grade 47 |
No. of Cylinder(s) 6.6 |
|||||
Packaging Purified |
Grade 47 |
No. of Cylinder(s) 6.6 |
|||||
Packaging 50 |
Grade 9.1 |
No. of Cylinder(s) 200 |
|||||
Packaging ALPHAGAZ™ 1 |
Grade 50 |
No. of Cylinder(s) 9.1 |
|||||
Packaging Ultra High Purity |
Grade 47 |
No. of Cylinder(s) 6.6 |
No. of Outlet(s) 150 |
||||
Grade Industrial |
No. of Cylinder(s) 16 |
No. of Outlet(s) 2 |
Water Capacity (L) 800 |
Content (m³) 145.6 |
Gas Pressure (bar) 200 |
||
Packaging Purified |
Grade 752 |
No. of Cylinder(s) 105.6 |
No. of Outlet(s) 150 |
||||
Packaging 800 |
Grade 145.6 |
No. of Cylinder(s) 200 |